BCS-V-WT

  • Availability: Exists

BCS-V-WT

BlackBody, a module for calibrating BCS VIEW thermal imaging cameras BCS-V-TI432IR5-TTW-15, BCS-V-TI432IR5-TTW-13, BCS-V-TI432IR5-TTW-10, BCS-V-TI432IR4-TTW-6 and BCS-V-EI432IR1-TTW-6

Calibration is performed by imitation of a black body (absorbing all thermal radiation from the environment) and emission of heat at a constant temperature. Thanks to the use of BlackBody, the measurement accuracy is +/- 0.3 ° C (without the calibration module +/- 0.5 ° C).

When using BlackBody, the camera does not need to be pre-calibrated after activation, which is responsible for adjusting the camera to thermal background and ambient temperature. With BlackBody, you can therefore save time and take temperature measurements almost immediately.

BCS-V-WT increases the camera's resistance to factors that may have a negative impact on the measurement, such as the movement of air masses (from fans or air conditioning) or thermal shadows (formed on the surfaces reflecting radiation).

Features of BCS-V-WT

  • Temperature reference for thermal imaging cameras to measure body temperature
  • Increased measurement accuracy to ± 0.1 ° C
  • Temperature stability ± 0.1 ° C / h
  • Effective area size 70mm × 70mm
  • Temperature range 5 ° C to 50 ° C
  • Effective emissivity 0.97 ± 0.02
  • Power AC 100 ~ 240V, 20W
  • Compact size 120mm × 176.6mm × 119.6mm (4.72 "× 6.95" × 4.71 ")
  • Weight 1.85kg
  • Easy to install and configure
  • Operating conditions 0 ° C to 40 ° C

Download